ASABE Technical Library - Abstract
Member and Access Notice
Design of a PVC Pipe System for Brooding Chickens
Published by the American Society of Agricultural and Biological Engineers, St. Joseph, Michigan www.asabe.org
Citation: Transactions of the ASAE. 31 (2):0552-0557. (doi: 10.13031/2013.30746) @1988Authors: Garrett L. Van Wicklen, Michael Czarick
Keywords:
ABSTRACT THE use of PVC pipe to transfer heat from circulating water to chickens during brooding was examined. A simulation was used to design different brooder characteristics such as pipe diameter, pipe material, water flow rate, and inlet water temperature as a result of their influence on heat transfer. The simulation was verified by comparing heat transfer of a prototype brooder which contained 17.5 m of nominal 19 mm diameter PVC pipe with simulation data. A test of the prototype brooder unit in a controlled environment chamber using 70 chicks showed that birds accepted the pipe as a source of heat and were physically compatible with the brooder configuration. A brooder unit constructed with 75 m of nominal 32 mm diameter PVC pipe with outer dimensions of 2.4 x 6.1 m was recommended for commerical broiler brooding. A pair of brooder units would be capable of transferring between 3700 to 4300 W of heat using a water flow rate of 0.064 L/s with an inlet temperature of 60 C with a brooding capacity of 1665 birds. Twelve pairs of brooder units would be recommended for a 12.2 x 122 m curtain sidewall broiler house using half-house brooding in the Southeastern U.S.
(Download PDF) (Export to EndNotes)