ASABE Technical Library - Abstract
Member and Access Notice
In-Field Evaluation of Pressure-Compensated Subsurface Drip Irrigation
Published by the American Society of Agricultural and Biological Engineers, St. Joseph, Michigan www.asabe.org
Citation: 2009 Reno, Nevada, June 21 - June 24, 2009 097144.(doi:10.13031/2013.29164)Authors: Tyrel L Harbuck, John P Fulton, Mark P Dougherty, Steve T Taylor, Larry P Curtis, Donald J Eakes, Jeff L Sibley
Keywords: Drip/trickle/micro irrigation, distribution, uniformity, emitter flow, test procedure
In the southeast U.S., an increasingly-popular precision irrigation practice is the utilization of Subsurface Drip Irrigation (SDI) to supply water to crops. Its popularity can be contributed to its application in small-irregular fields, lower energy requirement and higher water-use efficiency compared to pivot irrigation. An SDI tape product was installed in 2003 in a 6.1-ha (15-acre) field in Northern Alabama to evaluate water-use efficiencies of a variety of agronomic crops. Despite the use of pressure-compensating emitters, observed moisture variability across the study site and within plots suggested either clogged emitters or flow rate differences between emitters. However, excavating soil from sections of the SDI product in order to conduct emitter-uniformity testing was infeasible due to the soil-profile disturbance impacting ongoing research and time commitment to unearth and conduct such an in-field analysis. Therefore, the objectives of this study were to 1) develop and validate an in-situ testing methodology to assess SDI product application uniformity, and 2) determine whether variable operating pressure or terrain slope impacts application uniformity. Laboratory tests were initially conducted over a range of operating pressures (48, 83, 117, and 138 kPa; 7, 12, 17, and 20 psi) in order to anticipate new-product performance; as expected, neither operating pressure nor slope affected the performance of the samples. Next, the experimentation plot was spatially evaluated to determine testing locations based on apparent surface slope. A testing apparatus was then fabricated to interface with the SDI product in order to deliver water over a range of operating pressures while determining sample discharge. This apparatus was tested in laboratory conditions in order to compare population-discharge values derived from the apparatus with per-emitter discharge values; apparatus estimates agreed within one percent of per-emitter discharge rates, so we determined the equipment and the methodology were sound. Surface-slope modeling was not an accurate predictor for drip-line slope estimation, so SDI slope effect could not be fully evaluated as anticipated in this study. Neither system activity (as indicated by irrigated or non-irrigated SDI lines within the plot) nor variable operating pressure had an effect on discharge values; however, certain testing samples exhibited questionable flow. Spatial yield data were compared with sample locations to determine if yield was affected by potential SDI clogging in the location in question Lint yield from the suspect location was equal to the yield across all irrigated plots (1.26 bales/ha), but the individual irrigated plot that contained the suspect sample witnessed the lowest yield (1.12 bales/ha) for the irrigation treatment. In this situation, irrigation variability relative to the rest of the experiment plot should be considered. Conclusion was that this equipment and methodology can help provide a less intrusive method to evaluate in-situ SDI performance.
(Download PDF) (Export to EndNotes)