ASABE Technical Library - Abstract
Member and Access Notice
Particulate Matter Emissions from a High-rise Layer House in Iowa
Published by the American Society of Agricultural and Biological Engineers, St. Joseph, Michigan www.asabe.org
Citation: 2009 Reno, Nevada, June 21 - June 24, 2009 095951.(doi:10.13031/2013.27440)Authors: Shuhai Li, Hong Li, Hongwei Xin, Robert T Burns
Keywords: Particulate matter, poultry, layer house
Particulate matter (PM) in animal feeding operations is a concern for the occupants and the surrounding community. Baseline measurements of the concentration and emission rate of PM are the first step toward assessing the environmental impact of animal feeding operation and evaluating the effectiveness of dust control strategies. This study presents the results of the PM measurement at a high-rise layer house in central Iowa. The average PM10 emission rate over the 9-month measurement period was 21.6 (10 S.D.) mg/bird/day. Comparing with the emission rates reported literature, the mean and range of PM10 emission from high-rise layer hen barns using cage systems were 33.5 and 19-48 mg/bird/day. The average PM2.5 emission rate over the measurement period was 2 ( 1.5 S.D.) mg/bird/day, which is less than literature values of 3.52-14.2 mg/bird/day.
(Download PDF) (Export to EndNotes)