A Simple Method to Measure the Flow Rate and Volume from Tile Drainage Pump Stations
Published by the American Society of Agricultural and Biological Engineers, St. Joseph, Michigan www.asabe.org
Citation: 2009 Reno, Nevada, June 21 - June 24, 2009 096997.(doi:10.13031/2013.27284)Authors: Thomas F Scherer, Xinhua Jia
Keywords: Tile Drainage, Drainage Discharge, Pump Station, Sump, Current Sensor, Datalogger
Measurement of flow characteristics from tile drainage pump stations has always been difficult. In a typical pump station, float controls are used to turn the pump on and off. This intermittent discharge is difficult to measure accurately with standard flow measurement devices... Indirect measurement of flow and volume was accomplished using a current switch connected to an event datalogger. The on and off periods were time stamped to the nearest half second and these data, when combined with the pump characteristic curve, the sump storage volume and lift distance, provided volume and flow rate estimates for the tile drainage system. The accuracy of the flow rate estimation is within 3.5 percent of the value obtained from the pump curve. From April to November of 2008, this method was used to estimate the discharge from a pump station that handled the outflow from a 20-hectare tile drained field. When the time and volume of pump discharge is combined with time-stamped rainfall amounts, other drainage response parameters could be estimated or calculated.