ASABE Technical Library - Abstract
Member and Access Notice
Water Consumption of Evaporative Pads
Published by the American Society of Agricultural and Biological Engineers, St. Joseph, Michigan www.asabe.org
Citation: 2009 Reno, Nevada, June 21 - June 24, 2009 096728.(doi:10.13031/2013.27277)Authors: Joseph P Harner, John F Smith, Richard Zimmerman, Matt VanBaale
Keywords: Water usage, evaporative cooling, cooling systems
Water meters were installed on a 113 m (372 ft) wide and 118 m (390 ft) long low- profile, cross-ventilated dairy using evaporative cooling in the upper Midwest. The evaporative pad along the west side measured 3 m (10 ft) by 107 m (350 ft). The water usage per unit surface area of the evaporative pad equaled 0.19 L/min/ m2 (0.286 gph/ft2) of evaporative pad surface area. The total daily water usage per stall averaged 49 L (13 gal) with a maximum of 85.8 L (22.7 gal). This data from this study suggest peak hourly water usage may be as much as 3 times the average values. This is an important consideration to remember in sizing the water system. The evaporative pad efficiency observed between 12 and 8 p.m. was 65 percent and between 0 and 4 a.m. was 79 percent.
(Download PDF) (Export to EndNotes)