ASABE Technical Library - Abstract
Member and Access Notice
Type-Independent Calibration Method for Microwave Moisture Sensing in Unshelled and Shelled Peanuts
Published by the American Society of Agricultural and Biological Engineers, St. Joseph, Michigan www.asabe.org
Citation: 2009 Reno, Nevada, June 21 - June 24, 2009 096136.(doi:10.13031/2013.27063)Authors: Micah A Lewis, Samir Trabelsi, Stuart O Nelson, Ernest W Tollner
Keywords: Dielectric properties, moisture content, shelled peanuts, unshelled peanuts, microwave sensing, complex permittivity, free space
A microwave dielectric method was used for nondestructive and instantaneous determination of moisture content in shelled and unshelled peanuts from measurement of their relative complex permittivities in free space at 6.0 GHz and 23C. Moisture content was determined independent of bulk density with the use of a density-independent calibration function. Statistical analysis provided the moisture calibration equations for each type with high coefficient of determination. The effectiveness of this method was further shown with the provision of a single moisture calibration equation for various types in shelled and unshelled peanut samples. Therefore, by using microwave moisture sensing, moisture content can be accurately predicted in different peanut types with a single calibration equation.
(Download PDF) (Export to EndNotes)