ASABE Technical Library - Abstract
Member and Access Notice
A LOW-COST TECHNIQUE TO MONITOR VENTILATION FAN OPERATION AT ANIMAL BUILDINGS
Published by the American Society of Agricultural and Biological Engineers, St. Joseph, Michigan www.asabe.org
Citation: Proceedings of the Seventh International Symposium, 18-20 May 2005 (Beijing, China) Publication Date 18 May 2005 701P0205.(doi:10.13031/2013.18390)Authors: Ji-Qin Ni, Albert J. Heber, Teng T. Lim, Claude A. Diehl
Keywords: Air quality, air pollution, emission, vibration, sensor
When measuring emissions of gases, particulate, and odor from animal buildings, the ventilation
data are equally important as the concentration data, because emission rate of a pollutant is the
product of its concentration and the ventilation rate. However, effectively measuring and
monitoring building ventilation remains a technical challenge, especially in barns with numerous
fans. Although several measurement and monitoring techniques have been used in livestock barn
studies, they are either relatively expensive or unreliable.
A new technique was introduced for continuously monitoring exhaust fan operation in real-time
by detecting the vibration of its housing or frame member. A low-cost vibration sensor, a 2-
coductor cable, a signal filter, and a digital input channel are used for each fan. A laboratory test
was conducted to evaluate the technical viability of using the sensor in continuous vibration
conditions. A 4-month field test in layer barns was conducted to test the accuracy and life of
three vibration sensors, which were installed on the fan housings and cones. The fan operation
data was logged by a computer every minute. Coupled with simultaneous building static pressure
measurement, the continuous ventilation rate can be calculated by using the fan airflow vs.
pressure performance curve.
The advantages of this technique include low cost (only about 1% to 10% of the cost of other
tested techniques), simplicity, no interference by wind and dust, and the capability of directly
monitoring individual fans to avoid false signals caused by fan failure, fan management changes
or other problems. This paper describes the technique and presents the test results.