COOLING EFFECT ANALYSIS ON FOUR TYPES OF COOLING LYING-BEDS FOR PIGS
Published by the American Society of Agricultural and Biological Engineers, St. Joseph, Michigan www.asabe.org
Citation: Proceedings of the Seventh International Symposium, 18-20 May 2005 (Beijing, China) Publication Date 18 May 2005 701P0205.(doi:10.13031/2013.18358)Authors: X.Y. Yuan, B. Li, G. Chen, Z.X. Shi, X.H. Ji
Keywords: Cooling lying-bed, the temperature difference, temperature ascend rate
In summer, cooling systems are applied in some swine buildings in China to alleviate heat stress
on pigs. Cooling lying-bed systems incorporating circulated water have been developed quickly
in China because they have advantages such as: no change of environmental humidity compared
to spraying cooling systems; and no high air speeds to blow over the pigs bringing unhealthy
conditions to pigs compared to the conventional ventilation system. An ideal cooling lying-bed
system should be circulated with low temperature water (15C-18C) for pigs experiencing
above30C ambient temperature. An excellent cooling lying-bed should provide high heat transfer
rates; the surface temperature should be comfortable for the pig lying on the pad; the cooling
water flow resistance should be low; and the price of each lying-bed should be affordable.
This paper discusses temperature difference between the surface and the water of four types of
cooling lying-beds at two running way, and the temperature ascend rate at simulative way. Four
types lying-bed include: #1 made of concrete and labyrinth water trough, #2 made of concrete
and iron water pipe buried in concrete, #3 made of iron plate-pipe covered 5mm thickness
concrete layer, #4 made of concrete water trough and concrete rib covered sealing iron gland.
Experiments showed that the temperature difference between the surface and water decreased in
order of #2, #4, #1 and #3. #3 showed the best cooling effect .The temperature ascend rate
increased in order of #1, #2, #3 and #4. #1 had the most heat capacity, which was suitable for
pigs lying on longest. #4 had the lowest thermal inertia. #3 had the highest cost for the plate-pipe
made of iron and #1, #2 and #4 had matched cost. However, #1 should be proposed