ASABE Technical Library - Abstract
Member and Access Notice
AIR EXCHANGE RATE IN A HORSE TRAILER DURING TRANSPORT
Published by the American Society of Agricultural and Biological Engineers, St. Joseph, Michigan www.asabe.org
Citation: Proceedings of the Seventh International Symposium, 18-20 May 2005 (Beijing, China) Publication Date 18 May 2005 701P0205.(doi:10.13031/2013.18343)Authors: J. L. Purswell, R.S. Gates, L.M. Lawrence, T.S. Stombaugh, R.J. Coleman, W.C. Adams
Keywords: Ventilation, tracer gas, animal transport
Ventilation of horse transport vehicles typically relies on vehicle motion to induce air exchange.
To assess the adequacy of ventilation in horse transport, air exchange rate was measured in ten
locations within a 4-horse trailer, with and without animals present, using tracer gas decay
measurements. Three vehicle speeds (13, 48, and 97 kmhr-1) and three window configurations
(all windows and roof vents closed, only side windows open, all windows and vents open) were
tested.
Air exchange rate increased with vehicle speed, and exchange rate at all points within the trailer
for the closed configuration was consistently lower than the other two window configurations.
The average air exchange rate over all vehicle speeds and ventilation configurations was 0.49
min-1 with animals present and 0.60 min-1 without. The maximum mean exchange rate was 1.42
min-1 at 97 kmhr-1 at the rear left window with all windows and vents open and no animals
present; the lowest exchange rate (at the lower position of the rearmost stall divider) was 0.12
min-1 at 13 kmhr-1 with all windows and vents closed. The maximum air exchange rate
observed with animals present was 0.84 min-1 with all windows and vents open, and traveling at
97 kmhr-1. Ventilation in the trailer was not adequate when compared to recommendations for
stabled horses for any combination of vehicle speed or ventilation configuration.