ASABE Technical Library - Abstract
Member and Access Notice
Using a Wind Tunnel to Determine Odor and Gas Fluxes from Manure Surfaces
Published by the American Society of Agricultural and Biological Engineers, St. Joseph, Michigan www.asabe.org
Citation: Paper number 024083, 2002 ASAE Annual Meeting . (doi: 10.13031/2013.10481) @2002Authors: David R. Schmidt, José R. Bicudo
Keywords: Wind tunnel, emissions, odor, hydrogen sulfide
A standard wind tunnel design for measuring gas fluxes from area sources is needed. This paper documents an attempt to design and test such a wind tunnel. Key parameters evaluated were tunnel wind speed, horizontal and vertical velocity profiles, and filter efficiency. Bulk speed in the wind tunnel can be varied between 0.1 and 1.2 m/s. The velocity profiles in the tunnel are fairly uniform and consistent. The activated charcoal filter on the inlet side of the wind tunnel reduced odor up to 85%, ammonia by 99% and hydrogen sulfide by 99%. Limited data on VOC reductions showed up to 100% reduction in some compounds but increases in other compounds.
(Download PDF) (Export to EndNotes)