Click on “Download PDF” for the PDF version or on the title for the HTML version.


If you are not an ASABE member or if your employer has not arranged for access to the full-text, Click here for options.

A Simple Method for Calibrating a Radial Gate for Use as a Flow Measuring Device

Published by the American Society of Agricultural and Biological Engineers, St. Joseph, Michigan www.asabe.org

Citation:  Applied Engineering in Agriculture. 34(2): 379-388. (doi: 10.13031/aea.12199) @2018
Authors:   Gabriele Bonaiti, Askarali Karimov, Guy Fipps
Keywords:   Flow meter calibration, Gate opening, Hysteresis, Submerged orifice equation.

Abstract. A simple method for the calibration and use of an existing radial gate as flow measuring device under submerged flow conditions is presented. Details on equipment and calibration methodology are discussed including: determining required gate opening parameters and flow conditions for which the method is valid. Flow is calculated with a submerged orifice equation using a constant drainage coefficient. This methodology was applied to a radial gate located in the United Irrigation District in South Texas. The gate was instrumented and monitored continuously over a three-month period. Measured versus predicted flow varied by less than 4%. The method was compared to a more complex equation which accounts for submerged flow conditions and results in a mean absolute relative error of 3%. Analysis of individual flow events revealed significant hysteresis when estimating gate opening from an actuator position signal. This accounted for a difference in the calculated flow of up to 0.13 m3 s-1.

(Download PDF)    (Export to EndNotes)